aluminium radiators manufacturer, air coolers suppliers, Aluminium Brazed Condenser
 
varun radiators, radiators, condensers, intercoolers, brazed alluminium intercoolers Brazed Condensers, aluminium heat exchangers, aluminium brazed radiators radiators, Radiators suitable for TATA Motors, Farm Tractor Radiators, Varun Radiators Condensers, Brazed Condensers, Brazed Alluminium Condensers, Appliances Condensers Intercoolers, Charger coolers, Brazed Alluminium Intercoolers, Charger Air Coolers, Engine Cooling Modules Heat Exchangers, Heat Exchanger Solutions, Industrial Heat Exchangers Brazed Condensers, Brazed Alluminium Intercoolers, Industrial Heat Exchangers, aluminium brazed condensers manufacturers varun radiators, radiators, condensers, Intercoolers
 
Radiators, Condensers, Intercoolers, Brazed Condensers, Radiator Assembly, Heat Exchangers, Brazed Alluminium Condensers, Varun Radiators  
 
Our quality systems are independent of production & base of our work ethic.
All International routine & type tests like Air Pressure Test, Vibration Test, Pressure Impulse Test, Internal & External Corrosion Test, Wind Tunnel Test are conducted on our radiators as per the BIS / A STM / JIS standards,
Stringent quality checks right from the receipt of raw material to final inspection of the finished goods are conducted regularly. Quality audit at predetermined intervals is the norm. We are Bureau Veritas certified ISO: 9001:2000 Company.
 
 
Sr. No. Test Purpose Specifications Remarks Test Location Test Criteria
1**
Salt spray Test To check external corrosion 5% commercial grade Nacl by weight for 72 hours   EQDC,
Gandhinagar
When matl.Spec changes
2**
Internal corrosion To check the internal corrosion of core/radiators 5% commercial grade Nacl by weight for 72 hours   EQDC,
Gandhinagar
When matl.Spec. changes
3**
Vibration test To check the strength of solder joints against vibration 33HZ, 1.2mm to 4.2mm Amplitude, two dimensional test. As per BIS standard EQDC,
Gandhinagar
Random
4**
Pressure impulse test To check the leak -proof assurance against cyclic pressure(Low-High pressure Impacts) 0 to 2 kg/cm2 g,7.5/15 cycle per minute, Total-10000 cycles As per BIS standard EQDC, Gandhinagar Random
5**
Heat Dissipation performance/wind tunnel test To check the ability of heat dissipation rate of radiator at given condition Temperature difference of air and water at inlet is 60 As per BIS standard IIT Chennai,
HAL Bangalore
Random
6*
Pressure Test To check the Leak-Proof joints of radiators assembles at given pressure Test pressure is taken doubled the pressure of working pressure. As per BIS standard In house 100%
7*
Visual Examination To check the finishing /aesthetics of radiators before dispatch As per Pre dispatch check list Separate check list for Cu-Brass & Aluminum Radiators In house 100%
 
*
  Routine Tests: applicable to each heat exchanger being produced
**
  Type Tests: applicable on case to case basis with regard to
 
a)
New developed model / prototype radiators.
c)
modified / changed design radiators.
b)
Specific customer requirement.
d)
Periodic quality checks for performance consistency.
 
Radiators, Intercoolers, Condensers, Aluminium Radiators Manufacturer, Heat Exchanger Solutions, Brazed Alluminium Intercoolers
Products : Brazed Aluminium radiators | Brazed Aluminium condensers | Brazed aluminium intercoolers